EFFICIENT OPERATION AND TROUBLESHOOTING OF CENTRALIZED CHILLED WATER HVAC SYSTEM

20 - 21 JANUARY 2027

16 CDP Approved by ST

COURSE INTRODUCTION

This programme develops a practical understanding of centralized chilled-water HVAC systems, from the chiller plant and cooling-water loop to chilled-water distribution, air-handling units and air distribution. Participants explore how system configuration, operating conditions and capacity modulation affect cooling performance and energy use. Practical calculations, psychrometric analysis, water-balancing methods and troubleshooting case studies connect equipment principles with day-to-day operation and maintenance.

COURSE OBJECTIVES

- Explain the configuration and heat-transfer processes of a centralized chilled-water HVAC system.
- Compare chiller types, operating principles and capacity-control methods.
- Relate cooling-tower performance, water treatment and pump operation to system efficiency.
- Evaluate cooling capacity, chilled-water flow and temperature difference.
- Understand water balancing, psychrometrics, air-handling units and air distribution.
- Apply structured troubleshooting to common chilled-water HVAC problems.

WHO SHOULD ATTEND

HVAC design engineers and facility and maintenance technicians responsible for centralized chilled-water air-conditioning systems. Participants should have a basic understanding of air-conditioning principles before attending.

COURSE CONTENT

- Session 1: System configuration and capacity modulation: chiller, cooling-tower and pump circuits, chilled-water and air-side systems; heat transfer from the building to ambient conditions; design conditions and energy-saving capacity control.
- Session 2: Chiller plant fundamentals: air- and water-cooled chillers; reciprocating, scroll, screw, centrifugal and absorption technologies; pressure-enthalpy charts, refrigerant pressure-temperature relationships, operating conditions and modulation.
- Session 3: Condenser-water systems: water-cooled condenser performance and fouling; cooling-tower range, approach and water treatment; condenser-pump flow, variable-speed control and water-cooled chiller case studies.
- Session 4: Chilled-water systems: secondary fluids and glycol applications; cooling-capacity calculations, temperature difference and flow; constant- and variable-flow circuits; causes and solutions for low delta-T.
- Session 5: Water balancing: flow measurement, balancing valves and proportional balancing methods for achieving appropriate water distribution.
- Session 6: Psychrometrics and humidity control: dry-bulb, wet-bulb and dew-point temperatures; humidity and psychrometric charts; heating, cooling, humidification, dehumidification and condensation problems.
- Session 7: Air-handling units and air distribution: fans, cooling coils, filtration, multizone arrangements, coil performance, control valves, variable-speed drives and primary AHUs; comfort, air quantity, CAV/VAV systems and common distribution issues.
- Session 8: Practical troubleshooting: chilled-water system case studies, discussion of client-specific operating problems, corrective approaches and questions and answers.

Hello

Thank you for your interest. Complete the form below and our team will send you the course information shortly.

Thank you for your enquiry. Our team will contact you shortly

Screenshote%20(2)_edited.jpg

Clients
 

109850

53

PARTNERS

PARTICIPANTS

23

3642

UNIQUE
CLIENTS

2025

34

319

CONFERENCES

WE ARE HERE TO STAY

INDUSTRIES

COURSES

TRAINERS

IK Academy has received the Best Training Provider Award by Malaysia's Ministry of Human Resources

AWARDS

we picked up along the way. . .

PSMB Awards
5 Start HRDF Awards
SME 100 Awards
MTPN.png
bottom of page